LF100 Tuning-Fork Point Level Switch

The LF100 is a tuning fork point level switch. Two piezoelectric crystals on the fork base drive the fork at its resonance frequency; the moment material touches the fork, the amplitude and frequency shift, the circuit detects the change and a switching signal is produced. Because the switch responds to a mechanical change rather than an electrical one, it does not care about the conductivity, dielectric constant, pressure or temperature of the medium, and it keeps working when the silo is dusty, foamed or coated. The fork is all stainless steel and the housing is sealed to IP68, so the instrument can be hosed down and can sit in a sump. It handles material with a density above 0.2 g/cm3 and a viscosity below 10,000 mm2/s, and four fork lengths are offered - 185 mm standard, up to 4 m extended, 100 mm short and a 40 mm micro fork for viscous liquids and small pipes. There is no calibration: mount it at the level to be detected, select high or low fail-safe and it is in service.

Email: marketing@longtec.com

Tel: 00864007808806

Whatsapp: 8618269775217

REQUEST A QUOTE
Main Functions
Applications
Spec Sheet
FAQ
Main Functions

· Tuning fork driven by piezo crystals: it switches on the mechanical change of the fork, not on an electrical property of the medium.

· Unaffected by conductivity, dielectric constant, pressure, temperature, foam, dust or build-up in the silo.

· All stainless steel fork and housing sealed to IP68, so wash-down and sump installation are both possible.

· Four fork lengths - 185 mm standard, up to 4 m extended, 100 mm short and a 40 mm micro fork for viscous liquids.

· Handles material from 0.2 g/cm3 density and viscosity up to 10,000 mm2/s, which covers powders and thick slurries alike.

· No calibration after installation: mount at the switching point, set the fail-safe mode and the switch is ready.

Applications

The LF100 is used for high and low level signals on cement, fly ash, sand, aggregate, grain, flour, starch, plastic pellets and powders in silos, hoppers, bins and chutes, and for liquid level and pump protection in tanks, sumps and process vessels. It is also used as a solid-liquid interface detector in settling tanks, and as a flow/no-flow proving switch on gravity chutes and small pipelines. In the cement industry it is the standard choice for kiln feed bins, clinker silos and dust collection hoppers, where dust and build-up defeat optical and capacitive switches.

Spec Sheet

LF100 spec table

FAQ

How does the fork know the silo is full?

The fork vibrates at its resonance frequency. When material covers it, the vibration is damped and the frequency shifts; the circuit sees that change and switches. Nothing is measured electrically through the product, which is why dust, moisture and changes in the material do not shift the switching point.

Which fork length should I order?

It depends on where the switching point sits relative to the mounting boss. The 185 mm fork covers most top-mounted high-level duties, the extended version reaches up to 4 m for deep bins and for low-level detection from the top, the 100 mm short fork fits confined spaces, and the 40 mm micro fork is for viscous liquids and small pipes.

Will build-up on the fork cause a false alarm?

A coating that is soft or light does not damp the fork enough to switch it, and the fork geometry sheds most dust. In very sticky products, mount the fork at an angle so material slides off, or use the micro fork version, which has a smaller wetted area.

Is it suitable for outdoor silos and wash-down areas?

Yes. The housing and fork are stainless steel and sealed to IP68, so the instrument can be installed outdoors and hosed down. The electrical entry should still be made off with a suitable gland and cable loop.

Can one instrument cover both powder and liquid?

Yes. The switch is independent of the dielectric constant and conductivity of the medium, so the same LF100 works in cement, sand, grain, plastic pellets and in water or slurry. What changes is the fork length and, for thick liquids, the choice of the micro fork.

Related Products

LV100 Vibrating-Rod Point Level SwitchLV100 Vibrating-Rod Point Level Switch
LF1000-Ex Explosion-Proof Tuning-Fork Point Level SwitchLF1000-Ex Explosion-Proof Tuning-Fork Point Level Switch
MTF Miniature Tuning-Fork Point Level SwitchMTF Miniature Tuning-Fork Point Level Switch
PFG86 Rotary-Paddle Point Level SwitchPFG86 Rotary-Paddle Point Level Switch
LB100 RF Admittance Point Level SwitchLB100 RF Admittance Point Level Switch
PL7300 Level TransmitterPL7300 Level Transmitter
LONGTEC

Solutions & Support

We go the extra mile to thoroughly analyze each project and deliver tailored business solutions that meet your specific requirements.

  • TR200H Analog Weighing Signal Transmitter
  • TR700L Digital Weight Transmitter
  • UNI800S Digital Weight Transmitter
  • UNI900D3 Digital Weighing Instrument
  • IM2000 Online Infrared Moisture Analyzer
  • Company Profile
  • Why Choose Us 
  • Certificates
  • Company Partners
  • Privacy Policy
  • Tel: 400-7808-806
  • E-mail:marketing@longtec.com
  • Address:No. 3 Jinliang Road, Hongqi Town, Jinwan District, Zhuhai City, Guangdong Province, China

Copyright © 2026 singoo Technical supp

  • Whatsapp

  • Inquiry

Contact US

×