UNI900A3 Weighing Indicator
The LONGTEC UNI900A3 is a weighing indicator built around a 256 x 64 dot-matrix OLED screen, so the weight, unit, setpoints and menus stay readable from a distance and in poor light. A 32-bit processor drives a delta-sigma front end with 1:16,000,000 internal resolution and up to 100 readings per second, giving 100,000 display divisions and a non-linearity of 0.005% FS. The display unit can be mounted separately from the instrument body, which lets you keep the electronics inside a cabinet while the screen sits on the panel door. Expansion slots cover 4-20 mA and 0-10 V analogue output, Modbus RTU, Modbus TCP, Profibus-DP, CC-Link, CANopen, EtherNet/IP and PROFINET, plus digital I/O for setpoint control. A metal housing and opto-isolated I/O suit grain, chemical, metallurgy, building material and energy plants.
· 256 x 64 dot-matrix OLED shows weight, unit, setpoints and menus clearly, even in dim cabinets and at a distance.
· Internal resolution of 1:16,000,000 and 100,000 display divisions resolve fine weight changes in large vessels.
· Display unit separates from the instrument body, so electronics can stay in the cabinet while the screen sits on the door.
· Expansion slots cover 4-20 mA, 0-10 V, Modbus RTU/TCP, Profibus-DP, CC-Link, CANopen, EtherNet/IP and PROFINET.
· Fixed-value control and weight comparison with 6DI4DO opto-isolated outputs handle dosing and setpoint switching directly.
· Metal housing, wide-range power supply (DC24V or AC85-265V) and opto-isolated I/O resist plant electrical noise.
UNI900A3 indicators are used where an operator needs to read weight locally while the signal also goes to a control system: batching and mixing plants, silo and hopper level monitoring, bagging and filling machines, tank farms, crane and platform scales, and analogue upgrades where old weighing systems have to move to a digital bus. Industries include grain and feed, chemical, building materials, metallurgy, non-ferrous metals, energy and machinery.



Can the display be mounted away from the electronics?
Yes. The OLED display unit is separate from the instrument body. The body can sit inside the cabinet on a DIN rail or mounting plate while the 168 x 68 mm display goes on the panel door, connected by ribbon cable.
Which analogue and fieldbus options are available?
Expansion slot 1 accepts 0-5 V, 0-10 V, 0-20 mA, 4-20 mA, Modbus RTU on RS232 or RS485, Modbus TCP, Profibus-DP, CC-Link, CC-Link IE, CANopen, EtherNet/IP or PROFINET. Slot 2 adds isolated RS-485 and slot 3 adds 6DI4DO.
How many display divisions can it show?
Up to 100,000 divisions, backed by an internal resolution of 1:16,000,000. That is enough for a large silo where 1 kg steps matter, or for a small batch scale that needs 10 g resolution.
Does it support setpoint and dosing control?
Yes. Fixed-value control and weight comparison are built in, and the optional 6DI4DO board gives opto-isolated outputs for feeders, valves or alarms. Inputs and outputs can also be switched through the menu or over the bus.
What supply voltage does it need?
Either DC24V or AC85-265V, selected by the model code. Both versions use the same metal housing, so the choice depends on what is already available in your cabinet.