TR700-EX-D3 Explosion-Proof Digital Weighing Instrument
The LONGTEC TR700-EX-D3 is a flameproof weighing instrument for areas where a spark is not allowed. It is a four-channel digital weighing system inside a cast aluminium Ex d enclosure rated IP65, with a 50 × 150 mm window and 25 mm high six-digit LED digits that can be read across a walkway. Because each of the four load cells is measured on its own channel, the instrument locates a faulty cell by number instead of reporting a general weight error, and a failed channel can be blocked so the batch continues. Corner adjustment is automatic and calibration is code-free or physical. Field wiring enters through three PT 1/2 cable entries, and communication covers Profibus-DP or PROFINET, Modbus TCP and Modbus RTU, so the instrument can be an Ex node on a normal plant network.
· Flameproof Ex d IIB T6 Gb and dust-tight Ex tD A20 IP65 T80 °C enclosure certified under CQCEx19.1236X.
· Four independent load cell channels inside the Ex enclosure, so no junction box is needed in the hazardous zone.
· 50 × 150 mm display window with 25 mm high six-digit LED digits, readable from a distance in a plant room.
· Per-channel diagnostics name the faulty cell, and a blocked channel keeps the batch running until the next shutdown.
· Automatic angle difference adjustment and code-free calibration, so commissioning does not need repeated vessel entry.
· Profibus-DP or PROFINET, Modbus TCP and Modbus RTU on RS-485, with three PT 1/2 cable entries for field wiring.
TR700-EX-D3 instruments are installed on reaction and mixing vessels, solvent and coating plants, paint and pigment production, pharmaceutical and food plants handling combustible dust, fertiliser and agrochemical lines, and any hopper or platform scale that sits inside a hazardous zone. The four-channel measuring system removes the junction box from the hazardous area, which is usually the hardest part of an Ex weighing installation to certify and maintain.



Which zones is the TR700-EX-D3 suitable for?
Gas zones where Ex d IIB T6 Gb equipment is accepted and dust zones covered by Ex tD A20 IP65 T80 °C. The certificate number is CQCEx19.1236X; please check your zone classification and local approval requirements before ordering.
Does it need a junction box in the hazardous area?
No. The four load cells are wired straight into the flameproof enclosure, one channel each. That removes a second Ex enclosure, its glands and its summing board from the installation.
How is the weight read and transmitted?
On the 25 mm six-digit LED display, and over Profibus-DP or PROFINET, Modbus TCP or Modbus RTU on RS-485. The communication ports are configured at order.
Can the enclosure be opened for service?
The cover is bolted and flameproof joints must not be damaged. Isolate the instrument before opening, and keep the joint faces clean and greased as specified. Day-to-day work such as calibration and channel checks is done from the keypad or over the network.
What ambient temperature is allowed?
-10 to 40 °C. Keep the enclosure out of direct sunlight and away from hot pipework, because the T6 rating depends on the surface temperature staying within the certified limit.