CD200HA Digital Weighing Acquisition Module
The LONGTEC CD200HA is the blind version of the CD200 weighing controller: the same measurement electronics, the same direct load cell connection and the same diagnostics, built into a sealed stainless-steel field enclosure instead of a DIN-rail housing. There is no display and no keypad, which is exactly what a plant wants when the instrument belongs inside a cabinet, on a platform or next to the vessel and the operator reads the weight on an HMI. Load cells are wired straight to the module, one channel each, so a faulty cell is identified by channel rather than reported as a general weighing error. Calibration is code-free from a PC or done physically, and the module carries CAN, two RS-485 ports, Ethernet with Modbus TCP / EtherNet/IP and a configurable analogue output, so it can feed a PLC, a DCS, a panel meter or the PWC cloud platform at the same time.
· Same measurement electronics as the CD200 controller in a sealed stainless-steel field enclosure without display or keypad.
· Load cells connect directly to the module, one channel per cell, so no summing junction box is needed on the vessel.
· Per-channel diagnostics identify the exact faulty cell, including broken excitation, shorted or reversed signal wiring.
· CAN, two RS-485 ports, Ethernet with Modbus TCP and EtherNet/IP plus a configurable analogue output are all on board.
· Code-free calibration from a PC and physical calibration on site, with calibration errors prompted instead of silently accepted.
· Built for PWC and cloud integration: weight data is mapped transparently over CAN without writing a PLC communication program.
CD200HA modules are installed where a weighing instrument has to live in the field: hopper and silo weighing in feed mills and grain depots, batching and mixing tanks in chemical and building-material plants, loss-in-weight feeders, and remote weighing points that report to a central PWC or SCADA system. Because the enclosure is sealed with cable glands and has no front panel, it is also the practical choice for wash-down areas, dusty silos and machinery frames where a display would not survive.


What is the difference between the CD200 and the CD200HA?
They share the same measuring electronics, calibration and diagnostics. The CD200 is a DIN-rail unit with an OLED display and keys; the CD200HA is the same board in a sealed stainless-steel field enclosure with no display or keypad, for cabinets and remote weighing points.
How do I read the weight if there is no display?
Through the communication ports or the analogue output. Most plants read it on an HMI or PLC over Modbus TCP, RS-485 or CAN; a 4-20 mA or 0-10 V signal is available for a panel meter or a drive.
Can it be mounted outside, close to the vessel?
Yes. The enclosure is sealed and the cables enter through glands, so the module can sit on a platform or a frame near the scale instead of running load cell cable back to the control room. Keep it within its -5 to 45 °C working range and out of direct wash-down jets.
Does a failed load cell stop the weighing?
No. The module reports which channel failed and continues on the healthy cells with a fault-tolerant algorithm. A replacement cell can be connected and its parameters written in without a full recalibration.
Can several CD200HA modules work together?
Yes. They can be distributed on the CAN bus and integrated into a PWC system, where each module reports its channels transparently to the master without custom PLC code.