CD200HA Digital Weighing Acquisition Module

The LONGTEC CD200HA is the blind version of the CD200 weighing controller: the same measurement electronics, the same direct load cell connection and the same diagnostics, built into a sealed stainless-steel field enclosure instead of a DIN-rail housing. There is no display and no keypad, which is exactly what a plant wants when the instrument belongs inside a cabinet, on a platform or next to the vessel and the operator reads the weight on an HMI. Load cells are wired straight to the module, one channel each, so a faulty cell is identified by channel rather than reported as a general weighing error. Calibration is code-free from a PC or done physically, and the module carries CAN, two RS-485 ports, Ethernet with Modbus TCP / EtherNet/IP and a configurable analogue output, so it can feed a PLC, a DCS, a panel meter or the PWC cloud platform at the same time.

Email: marketing@longtec.com

Tel: 00864007808806

Whatsapp: 8618269775217

REQUEST A QUOTE
Main Functions
Applications
Spec Sheet
FAQ
Main Functions

· Same measurement electronics as the CD200 controller in a sealed stainless-steel field enclosure without display or keypad.

· Load cells connect directly to the module, one channel per cell, so no summing junction box is needed on the vessel.

· Per-channel diagnostics identify the exact faulty cell, including broken excitation, shorted or reversed signal wiring.

· CAN, two RS-485 ports, Ethernet with Modbus TCP and EtherNet/IP plus a configurable analogue output are all on board.

· Code-free calibration from a PC and physical calibration on site, with calibration errors prompted instead of silently accepted.

· Built for PWC and cloud integration: weight data is mapped transparently over CAN without writing a PLC communication program.

Applications

CD200HA modules are installed where a weighing instrument has to live in the field: hopper and silo weighing in feed mills and grain depots, batching and mixing tanks in chemical and building-material plants, loss-in-weight feeders, and remote weighing points that report to a central PWC or SCADA system. Because the enclosure is sealed with cable glands and has no front panel, it is also the practical choice for wash-down areas, dusty silos and machinery frames where a display would not survive.

Spec Sheet

CD200HA spec table

CD200HA interface

FAQ

What is the difference between the CD200 and the CD200HA?

They share the same measuring electronics, calibration and diagnostics. The CD200 is a DIN-rail unit with an OLED display and keys; the CD200HA is the same board in a sealed stainless-steel field enclosure with no display or keypad, for cabinets and remote weighing points.

How do I read the weight if there is no display?

Through the communication ports or the analogue output. Most plants read it on an HMI or PLC over Modbus TCP, RS-485 or CAN; a 4-20 mA or 0-10 V signal is available for a panel meter or a drive.

Can it be mounted outside, close to the vessel?

Yes. The enclosure is sealed and the cables enter through glands, so the module can sit on a platform or a frame near the scale instead of running load cell cable back to the control room. Keep it within its -5 to 45 °C working range and out of direct wash-down jets.

Does a failed load cell stop the weighing?

No. The module reports which channel failed and continues on the healthy cells with a fault-tolerant algorithm. A replacement cell can be connected and its parameters written in without a full recalibration.

Can several CD200HA modules work together?

Yes. They can be distributed on the CAN bus and integrated into a PWC system, where each module reports its channels transparently to the master without custom PLC code.

Related Products

TR200H Analog Weighing Signal TransmitterTR200H Analog Weighing Signal Transmitter
TR700L Digital Weight TransmitterTR700L Digital Weight Transmitter
TR700C Multi-Material Batching ControllerTR700C Multi-Material Batching Controller
TR700-LF Loss-in-Weight Feeding Control ModuleTR700-LF Loss-in-Weight Feeding Control Module
TR700-BC Belt-Scale Batching Control ModuleTR700-BC Belt-Scale Batching Control Module
TR700M Intelligent Multi-Channel Weight TransmitterTR700M Intelligent Multi-Channel Weight Transmitter
LONGTEC

Solutions & Support

We go the extra mile to thoroughly analyze each project and deliver tailored business solutions that meet your specific requirements.

  • TR200H Analog Weighing Signal Transmitter
  • TR700L Digital Weight Transmitter
  • UNI800S Digital Weight Transmitter
  • UNI900D3 Digital Weighing Instrument
  • IM2000 Online Infrared Moisture Analyzer
  • Company Profile
  • Why Choose Us 
  • Certificates
  • Company Partners
  • Privacy Policy
  • Tel: 400-7808-806
  • E-mail:marketing@longtec.com
  • Address:No. 3 Jinliang Road, Hongqi Town, Jinwan District, Zhuhai City, Guangdong Province, China

Copyright © 2026 singoo Technical supp

  • Whatsapp

  • Inquiry

Contact US

×