CD200 Digital Weighing Solution Controller
The LONGTEC CD200 is a DIN-rail weighing controller that removes the junction box from the weighing circuit. Each load cell is wired straight to the instrument, so every channel is measured and monitored on its own instead of being summed in a box on the vessel. A faulty cell, a broken excitation line, a shorted signal line or a reversed connection is reported against the exact channel it belongs to, which turns a day of cable tracing into a one-minute check. Calibration can be done code-free on a PC, and the angle difference of a platform can be trimmed on the instrument itself rather than inside a junction box. Two independent communication channels - RS-485 and CAN - let the controller talk to a PLC or DCS and to the PWC system at the same time, and a fault-tolerant algorithm keeps production running on the remaining cells when one fails.
· Load cells connect straight to the controller, so no junction box is needed and every channel is measured separately.
· Per-channel fault detection names the exact cell with a broken excitation, shorted or reversed signal line for fast repair.
· Code-free calibration from a PC plus physical calibration, with angle difference trimmed directly on the instrument.
· Two independent communication channels, RS-485 and CAN, allow a PLC link and PWC integration at the same time.
· Fault-tolerant algorithm keeps the scale running on the healthy cells, so a single sensor failure does not stop production.
· Unique digital filter removes the disturbance caused by agitators and external forces acting on the weighing vessel.
CD200 controllers are used wherever a vessel or platform is weighed with several load cells: hopper and silo scales, mixing and batching tanks, reactor weighing, loss-in-weight feeding, bagging and filling machines, and test stands in grain, feed, chemical, building material, metallurgy and machinery plants. The direct cell connection and per-channel diagnostics suit installations where the junction box sits in a hot, wet or hard-to-reach place and a single bad cell used to stop the whole line.



Do I still need a junction box with the CD200?
No. The load cell cables run straight into the controller terminals, one channel per cell. Removing the junction box also removes its summing board, its drift and its usual hiding place for a bad connection.
What happens when one load cell fails?
The CD200 reports which channel is faulty and keeps working with the remaining cells through a fault-tolerant algorithm, so the vessel stays in service. The failed cell can be replaced and its parameters written into the instrument without recalibrating the whole scale.
How is the scale calibrated?
Two ways: code-free calibration operated from the upper computer, and physical calibration with test weights. Calibration errors are prompted on screen instead of being silently accepted.
Can I adjust the angle difference on the instrument?
Yes. The corner adjustment is done on the CD200 itself, with a wider range than a junction box potentiometer, so a platform can be levelled without opening the box on the vessel.
How does it connect to a PLC or DCS?
Through RS-485 (Modbus RTU) and CAN, which are independent and can be used at the same time. On the CAN side the controller can join a PWC system, where weight data is mapped transparently without writing a PLC communication program.