UD66 Online NIR Composition Analyzer

The UD66 is an online near-infrared composition analyzer for the process line. A DA7440 optical head looks at the product from about 250 mm without touching it, collects the diffuse reflectance spectrum between 900 and 1700 nm, and the software converts that spectrum into the constituents the plant actually controls: moisture, protein, fat, fibre, ash, sugar, or a polymer grade. The optical system uses a gold-coated holographic fixed grating with an electrically cooled 256-element InGaAs array and an internal linear wavelength reference, so the wavelength axis does not drift as the instrument warms or the lamp ages, and the automatic diffuse-reference plate re-references itself between measurements. The acquisition runs at more than 30 full spectra per second, which is fast enough to average several hundred spectra and still report once a second, and the whole instrument is a 95 x 461 x 210 mm enclosure running from 115-230 V AC.

Email: marketing@longtec.com

Tel: 00864007808806

Whatsapp: 8618269775217

REQUEST A QUOTE
Main Functions
Applications
Spec Sheet
FAQ
Main Functions

· Non-contact diffuse reflectance measurement at about 250 mm, so nothing touches the product and nothing wears out in the stream.

· Gold-coated holographic fixed grating with an electrically cooled 256-element InGaAs array and an internal wavelength reference.

· More than 30 full spectra per second, which averages out surface variation and still updates the reading once a second.

· Automatic standard diffuse reference plate re-references the instrument between measurements, so the calibration holds over a shift.

· Wavelength accuracy better than 0.05 nm and stability better than 0.2 nm per year, which is what keeps a chemometric model valid.

· 12,000 hour lamp life and a user-replaceable lamp, plus 950-1650 nm working range covering moisture, protein, fat and polymer bands.

Applications

The UD66 is used wherever a composition has to be known while the product is moving: grain and oilseed at intake and before storage, feed and flour milling, starch and sugar, dairy powder, tobacco, chemical and polymer powders, and mineral products on a belt. It can be mounted over a conveyor, at a chute outlet, over a falling stream or on a bypass sampler, and the non-contact presentation means nothing wears and nothing contaminates the product. The head is available in IP65 for general plant use and IP69K for wash-down areas, with a separate IP65 distribution box.

Spec Sheet

UD66 spec table

FAQ

What can it measure?

Moisture, protein, fat, fibre, ash, sugar, starch and similar constituents, plus polymer or blend parameters, depending on the calibration. The instrument measures a spectrum; the constituent values come from a chemometric model built from your product with laboratory reference values, so the model is the part that has to be made for your material.

Does the product have to be a powder?

No. The measurement is diffuse reflectance, so it works on powders, meals, grains, pellets, flakes and slurries as long as the surface is representative and the distance stays inside 200 to 350 mm. For a coarse or segregated stream, averaging over several hundred spectra per second is what makes the reading representative.

How is it mounted on the line?

On a 38 mm pipe stand over a conveyor, at a chute outlet or over a falling stream, at about 250 mm from the product. The head is non-contact and needs a clean air supply of 30 to 60 L/min at 0.1 to 0.4 MPa to keep the window clear; the distribution box can stand away from the hot or wet part of the plant.

What is the IP69K version for?

Wash-down areas, typically food, dairy and pharmaceutical plants where the equipment is cleaned with a jet. The standard GP head is IP65 for general plant use, and both connect to the same IP65 distribution box.

How does it stay calibrated?

The wavelength axis is referenced internally by a linear reference in the detector, and the instrument re-references against an automatic diffuse reference plate between measurements. Wavelength accuracy of 0.05 nm and stability of 0.2 nm per year are what allow a model to stay valid; routine verification is a reference scan plus a check sample, not a full recalibration.

Related Products

IM2000 Online Infrared Moisture AnalyzerIM2000 Online Infrared Moisture Analyzer
IM1500 Online Infrared Thickness GaugeIM1500 Online Infrared Thickness Gauge
HV200 Online High-Frequency Radar Moisture AnalyzerHV200 Online High-Frequency Radar Moisture Analyzer
RF2500 Online Variable-Frequency Radar Grain Moisture AnalyzerRF2500 Online Variable-Frequency Radar Grain Moisture Analyzer
ZA1000 Benchtop NIR Composition AnalyzerZA1000 Benchtop NIR Composition Analyzer
LUNA-ST High-Stability Miniature Fibre-Optic SpectrometerLUNA-ST High-Stability Miniature Fibre-Optic Spectrometer
LONGTEC

Solutions & Support

We go the extra mile to thoroughly analyze each project and deliver tailored business solutions that meet your specific requirements.

  • TR200H Analog Weighing Signal Transmitter
  • TR700L Digital Weight Transmitter
  • UNI800S Digital Weight Transmitter
  • UNI900D3 Digital Weighing Instrument
  • IM2000 Online Infrared Moisture Analyzer
  • Company Profile
  • Why Choose Us 
  • Certificates
  • Company Partners
  • Privacy Policy
  • Tel: 400-7808-806
  • E-mail:marketing@longtec.com
  • Address:No. 3 Jinliang Road, Hongqi Town, Jinwan District, Zhuhai City, Guangdong Province, China

Copyright © 2026 singoo Technical supp

  • Whatsapp

  • Inquiry

Contact US

×