Home  >  Products  >  Analytical Instruments  >  IM1500 Online Infrared Thickness Gauge
im1500-01-main-white.webp
im1500-02-clamp-detail.webp
im1500-01-main-white.webp
im1500-02-clamp-detail.webp

IM1500 Online Infrared Thickness Gauge

The LONGTEC IM1500 measures coating weight, film thickness and moisture on a moving web without touching it. Its head carries a dual optical path with four wavelengths and eight beams, plus a built-in reference channel, so the instrument compares the light returning from the coating against a clean internal path and corrects the drift that normally sends a near-infrared gauge out of calibration. An InGaAs thermoelectrically cooled detector holds the signal steady through a shift, and the 3-inch lens keeps a usable signal through the dust that builds up over a coating station. Because the optics are matched to C-H and O-H absorption, the IM1500 also reads dark and black coatings, which ordinary infrared gauges struggle with. The probe hangs 150-200 mm above the web on a Ø38 clamp bracket, and the wall-mounted display box holds the calibration curves, shows the value on a 7.4-inch touch screen and outputs 4-20 mA, RS485 Modbus RTU or Modbus TCP to the line control system. Typical jobs are PSA label stock, adhesive tape, coated and thin paper, thermoplastic and solar film, PVDC and polymer coating, aluminium foil lacquer and silicone release liner.

Email: marketing@longtec.com

Tel: 00864007808806

Whatsapp: 8618269775217

REQUEST A QUOTE
Main Functions
Applications
Spec Sheet
FAQ
Main Functions

· Dual optical path with four wavelengths and eight beams, plus a built-in reference channel that corrects optical drift automatically.

· InGaAs thermoelectrically cooled detector and a 35 W stabilised halogen source keep the signal stable over long production runs.

· Measures coating weight from 0 to 600 gsm and moisture from 0 to 50 % on the same head, without contact with the web.

· 3-inch lens and air purge resist dust and steam, so the window stays clean and the reading stays on calibration.

· High sensitivity and signal-to-noise ratio let it measure dark and black coatings that standard infrared gauges cannot read.

· Wall-mounted touch-screen display holds the calibration curves and outputs 4-20 mA, Modbus RTU and Modbus TCP.

Applications

The IM1500 is built for coating and converting lines where the coat weight has to be held continuously: PSA label paper and adhesive tape, coated paper and thin paper, laminated and sandwiched materials, thermoplastic film, solar backsheet film, PVDC and polymer coating, aluminium foil lacquer, flexible and industrial packaging, silicone release liner, and coated steel or aluminium strip. It is mounted after the coating head for a wet reading close to the applicator, or after the dryer for a direct dry coat weight, and the 4-20 mA output can trim the coating head or the dryer without an operator in the loop.

Spec Sheet

IM1500 spec table

IM1500 dimensions

FAQ

What can it measure besides coating weight?

Moisture on the same optical head, from 0 to 50 %, and film thickness through the coat weight reading. Coating weight covers 0 - 600 gsm. Which of the two you get depends on the wavelengths fitted, so tell us the material and the coat weight range when ordering.

Can it read black or dark coatings?

Yes, and that is one of its advantages. The dual optical path, cooled InGaAs detector and high sampling rate keep the signal-to-noise ratio high enough on dark surfaces, where a single-path infrared gauge usually runs out of signal.

Where on the line should the head be mounted?

Either just after the coating head for a wet reading, or after the dryer where the dry coat weight is measured directly. The lens sits 150 - 200 mm above the web, and the head must not be in direct sunlight. For a wet reading, keep the head close to the applicator so solvent loss does not distort the result.

How is it calibrated?

With laboratory samples taken from the line behind the measuring point. You enter the internal reading and the laboratory value for each sample; a two-point calibration is enough for most materials, and a ten-point calibration is used where the response is not linear. The curves are stored in the display box.

How does it connect to the line control system?

The display box provides a 4-20 mA output (maximum 300 Ω), RS485 with Modbus RTU and Modbus TCP over Ethernet, plus optional high/low limit relay outputs. The signal cable can run up to 500 m between the probe and the display box.

Related Products

IM2000 Online Infrared Moisture AnalyzerIM2000 Online Infrared Moisture Analyzer
HV200 Online High-Frequency Radar Moisture AnalyzerHV200 Online High-Frequency Radar Moisture Analyzer
RF2500 Online Variable-Frequency Radar Grain Moisture AnalyzerRF2500 Online Variable-Frequency Radar Grain Moisture Analyzer
ZA1000 Benchtop NIR Composition AnalyzerZA1000 Benchtop NIR Composition Analyzer
UD66 Online NIR Composition AnalyzerUD66 Online NIR Composition Analyzer
LUNA-ST High-Stability Miniature Fibre-Optic SpectrometerLUNA-ST High-Stability Miniature Fibre-Optic Spectrometer
LONGTEC

Solutions & Support

We go the extra mile to thoroughly analyze each project and deliver tailored business solutions that meet your specific requirements.

  • TR200H Analog Weighing Signal Transmitter
  • TR700L Digital Weight Transmitter
  • UNI800S Digital Weight Transmitter
  • UNI900D3 Digital Weighing Instrument
  • IM2000 Online Infrared Moisture Analyzer
  • Company Profile
  • Why Choose Us 
  • Certificates
  • Company Partners
  • Privacy Policy
  • Tel: 400-7808-806
  • E-mail:marketing@longtec.com
  • Address:No. 3 Jinliang Road, Hongqi Town, Jinwan District, Zhuhai City, Guangdong Province, China

Copyright © 2026 singoo Technical supp

  • Whatsapp

  • Inquiry

Contact US

×