LONGTEC
  • Home
  • Products
    • Complete Filling Line
    • Standalone Machines
    • Analytical Instruments
    • Weighing Products
    • Level Instruments
  • About Us
  • Case
  • News
  • Service
  • Contact Us
  • 日本語
  • English
  • Español
  • русский язык
  • Français
  • بالعربية
Home  >  Products  >  Analytical Instruments  >  LINA-PRO Single-Stage Cooled NIR Spectrometer
lina-pro-06-main-white.webp
lina-pro-01-cover.webp
lina-pro-02-dual-view-a.webp
lina-pro-03-dual-view-b.webp
lina-pro-04-key-specs.webp
lina-pro-05-typical-applications.webp
lina-pro-07-installed-module.webp
lina-pro-06-main-white.webp
lina-pro-01-cover.webp
lina-pro-02-dual-view-a.webp
lina-pro-03-dual-view-b.webp
lina-pro-04-key-specs.webp
lina-pro-05-typical-applications.webp
lina-pro-07-installed-module.webp

LINA-PRO Single-Stage Cooled NIR Spectrometer

The LINA-PRO extends the LINA range to 1900 nm and cools the detector. The InGaAs array of 256 or 512 pixels is mounted on a single-stage thermoelectric cooler, which suppresses dark current and lets the instrument reach a signal-to-noise ratio of 5000:1 at full signal and a dynamic range of 7000:1 in a single acquisition, against 2000:1 and 4000:1 for the uncooled LINA-ST. The extra 200 nm beyond 1700 nm matters because it includes the stronger first-overtone bands of moisture and of C-H and N-H bonds, which is where NIR methods for grain, oilseed, dairy powder and polymers get their sensitivity. Optical resolution is about 4.3 nm at a 50 um slit, stray light stays below 1 %, the A/D is 16 bit, integration runs from 1 ms to 10 s, and the 1.25 kg housing takes an SMA905 fiber with USB 2.0 Type-B and digital I/O.

Email: marketing@longtec.com

Tel: 00864007808806

Whatsapp: 8618269775217

REQUEST A QUOTE
Main Functions
Applications
Spec Sheet
FAQ
Main Functions

· 900 to 1900 nm range adds the stronger first-overtone bands that sit beyond 1700 nm.

· Single-stage TEC cooling of the InGaAs array suppresses dark current and stabilises the baseline over a long run.

· Signal-to-noise ratio of 5000:1 at full signal, two and a half times the uncooled LINA-ST.

· Dynamic range of 7000:1 in a single acquisition, so a weak band next to a strong absorption still resolves.

· About 4.3 nm resolution at a 50 um slit, stray light below 1 % and a 16-bit A/D.

· 1.25 kg housing with SMA905 input, USB 2.0 Type-B and digital I/O, on Windows 7, 10 or 11.

Applications

The LINA-PRO is used for quantitative NIR methods where sensitivity matters: protein, fat and moisture in grain and oilseed, lactose and moisture in dairy powder, moisture in pharmaceutical granules and pellets, hydroxyl value and moisture in polymers, and alcohol or water in solvents and fuels. It is also used in process analysers and in portable instruments that need the 1700 to 1900 nm region and cannot tolerate the drift of an uncooled detector over a long shift.

Spec Sheet

LINA-PRO spec table

FAQ

What does the 1700 to 1900 nm extension add?

It adds the first overtone of the O-H stretch and stronger combination bands of C-H and N-H, which are the bands that give NIR its sensitivity for moisture, protein and fat. Methods that are marginal at 1700 nm become comfortable at 1900 nm.

How much does the cooler change the measurement?

It removes the dark-current drift that otherwise shows up as a baseline slope during a long integration or a long shift. With a 5000:1 signal-to-noise ratio and 7000:1 dynamic range, the instrument can use longer integration times without the noise floor rising, which is what a weak diffuse-reflectance signal needs.

Do I need to wait for the cooler?

A few minutes to reach its set point before a quantitative run, and the dark spectrum must be taken after that. Once stable, the instrument can run for hours without re-zeroing.

Which slit should I use for powder samples?

50 um is the usual choice: the NIR absorption bands of powders are broad, so 4.3 nm is enough resolution, and the wider slit gives the light throughput that a diffuse reflectance measurement needs.

Is the 1.25 kg housing a problem in an OEM instrument?

No. It is a benchtop module with a defined heat path for the cooler; the enclosure needs ventilation around the housing, but the footprint is small enough to fit inside a portable analyser.

Related Products

IM2000 Online Infrared Moisture AnalyzerIM2000 Online Infrared Moisture Analyzer
IM1500 Online Infrared Thickness GaugeIM1500 Online Infrared Thickness Gauge
HV200 Online High-Frequency Radar Moisture AnalyzerHV200 Online High-Frequency Radar Moisture Analyzer
RF2500 Online Variable-Frequency Radar Grain Moisture AnalyzerRF2500 Online Variable-Frequency Radar Grain Moisture Analyzer
ZA1000 Benchtop NIR Composition AnalyzerZA1000 Benchtop NIR Composition Analyzer
UD66 Online NIR Composition AnalyzerUD66 Online NIR Composition Analyzer
LONGTEC

Solutions & Support

We go the extra mile to thoroughly analyze each project and deliver tailored business solutions that meet your specific requirements.

  • TR200H Analog Weighing Signal Transmitter
  • TR700L Digital Weight Transmitter
  • UNI800S Digital Weight Transmitter
  • UNI900D3 Digital Weighing Instrument
  • IM2000 Online Infrared Moisture Analyzer
  • Company Profile
  • Why Choose Us 
  • Certificates
  • Company Partners
  • Privacy Policy
  • Tel: 400-7808-806
  • E-mail:marketing@longtec.com
  • Address:No. 3 Jinliang Road, Hongqi Town, Jinwan District, Zhuhai City, Guangdong Province, China

Copyright © 2026 singoo Technical supp

  • Whatsapp

  • Inquiry

Contact US

×