GY-HL05 5 W Halogen Broadband Light Source
The GY-HL05 is a compact tungsten halogen light source of 5 W with an SMA905 fiber output, sized to sit beside a miniature spectrometer or inside a portable instrument. A halogen filament is a black-body radiator, so its output is a smooth continuum from the visible into the near infrared, with no lines and no gaps: that is what makes it the standard source for absorbance, transmission and reflectance measurement, because every wavelength in the band is present at once. The 5 W version is the one to take when the optical path is short and the sample is transparent, or when the instrument is battery powered and the source has to be small and cool. The palm-sized housing and the fiber connector mean the source and the spectrometer can be treated as one optical unit, with the sample cell between them.
· Tungsten halogen filament gives a smooth continuum with no lines and no gaps, ideal for absorbance and reflectance.
· 5 W output suits a short optical path, a transparent sample and a battery-powered instrument.
· SMA905 fiber interface, so the source and the spectrometer form one optical unit with the sample between them.
· Palm-sized housing that fits beside a miniature spectrometer or inside a portable analyser.
· Stable continuum from the visible into the near infrared, covering the band of a CCD or CMOS spectrometer.
· No warm-up electronics and no moving parts: a filament, a lens and a fiber connector.
The GY-HL05 is used for absorbance and transmission measurement in cuvettes and flow cells, for reflectance measurement with a probe, for colour and spectral measurement of surfaces and liquids, for film and glass transmission, and as the source inside portable and integrated spectrometer systems. It is the usual partner of the LUNA and SLAK spectrometers for visible and short-wave near-infrared work.

Why a halogen lamp rather than an LED?
Because a halogen filament is a black-body radiator: it emits at every wavelength in the band at once, with no gaps. Absorbance and reflectance measurement need that continuum, since the sample is characterised by how much light it removes at each wavelength.
Is 5 W enough?
For a short path, a clear sample and a fiber-coupled setup, yes. If the path is long, the sample is turbid, or the fiber is thin, the 20 W GY-HL20 gives more light and an adjustable output.
Does it cover the ultraviolet?
No. A tungsten filament has almost no output below about 350 nm, so UV measurement needs a deuterium or deuterium-halogen source such as the GY-DL310.
How stable is the output?
A halogen filament is stable once it reaches thermal equilibrium, which takes a few minutes. For quantitative work, let it warm up and take a reference scan on the same schedule as the samples.
What fiber should I use?
A standard silica patch cord for visible and near-infrared work. Keep it short, because every metre of fiber costs light, and fix the connectors so the coupling does not change between the reference and the sample scan.