GY-DL310 Deuterium-Halogen Combined Light Source

The GY-DL310 combines a deuterium lamp and a tungsten halogen lamp in one housing with an SMA905 output, covering 200 to 2500 nm in a single fiber. The two sources are complementary by physics: deuterium emits a molecular continuum in the ultraviolet from 200 nm to about 400 nm, where a tungsten filament has essentially no output, and the halogen filament carries the visible and near infrared from 350 nm to 2500 nm. Together they give the continuous spectrum that UV-visible-NIR absorbance and transmission measurement needs, with no gap at the crossover where many analytical methods have their working wavelength. The output is adjustable, so the balance between the two lamps can be set for the method, and the single fiber output means one spectrometer sees the whole range without changing hardware.

Email: marketing@longtec.com

Tel: 00864007808806

Whatsapp: 8618269775217

REQUEST A QUOTE
Main Functions
Applications
Spec Sheet
FAQ
Main Functions

· Deuterium and halogen lamps in one housing, covering 200 to 2500 nm through a single SMA905 fiber.

· No gap at the crossover: the deuterium continuum and the halogen continuum overlap around 350 to 400 nm.

· Adjustable output, so the balance between the UV and the visible-near-infrared part can be set for the method.

· One fiber output means one spectrometer sees the whole range without changing source or hardware.

· Serves UV absorbance at 254 nm and near-infrared measurement in the same optical setup.

· Compact bench housing with a standard fiber connector, so it integrates with a miniature spectrometer directly.

Applications

The GY-DL310 is used for UV-visible-NIR absorbance and transmittance measurement, for HPLC and spectrophotometer sources, for water and wastewater analysis at 254 nm, for protein and nucleic acid measurement at 260 and 280 nm, for optical filter and glass transmission testing across the UV to near infrared, and for any method that needs the ultraviolet and the near infrared in the same scan.

Spec Sheet

GY-DL310 spec table

FAQ

Why two lamps in one housing?

Because no single lamp covers 200 to 2500 nm. Deuterium gives the ultraviolet continuum and the halogen filament gives the visible and near infrared; combining them closes the gap at about 350 to 400 nm, which is where many colorimetric and protein methods sit.

Does the deuterium lamp need to warm up?

Yes. A deuterium discharge needs several minutes to stabilise, and its output also ages over its life. Run a reference scan after warm-up, and re-reference on the schedule your method specifies.

How long do the lamps last?

The halogen filament and the deuterium tube have different lives, and the deuterium tube is usually the limiting one. Replace each when its output or its stability falls below the method requirement, and re-reference afterwards.

Can I use only one of the lamps?

The output is adjustable, and the balance between the two can be set for the method. If your measurement is purely visible, a halogen-only source such as the GY-HL20 is simpler and cheaper; the GY-DL310 is for methods that need the ultraviolet.

What fiber do I need for 200 nm?

A UV-grade silica fiber. Standard fiber absorbs strongly below about 250 nm, so the deuterium range is lost without it, and the fiber should be kept short to preserve the UV end.

Related Products

IM2000 Online Infrared Moisture AnalyzerIM2000 Online Infrared Moisture Analyzer
IM1500 Online Infrared Thickness GaugeIM1500 Online Infrared Thickness Gauge
HV200 Online High-Frequency Radar Moisture AnalyzerHV200 Online High-Frequency Radar Moisture Analyzer
RF2500 Online Variable-Frequency Radar Grain Moisture AnalyzerRF2500 Online Variable-Frequency Radar Grain Moisture Analyzer
ZA1000 Benchtop NIR Composition AnalyzerZA1000 Benchtop NIR Composition Analyzer
UD66 Online NIR Composition AnalyzerUD66 Online NIR Composition Analyzer
LONGTEC

Solutions & Support

We go the extra mile to thoroughly analyze each project and deliver tailored business solutions that meet your specific requirements.

  • TR200H Analog Weighing Signal Transmitter
  • TR700L Digital Weight Transmitter
  • UNI800S Digital Weight Transmitter
  • UNI900D3 Digital Weighing Instrument
  • IM2000 Online Infrared Moisture Analyzer
  • Company Profile
  • Why Choose Us 
  • Certificates
  • Company Partners
  • Privacy Policy
  • Tel: 400-7808-806
  • E-mail:marketing@longtec.com
  • Address:No. 3 Jinliang Road, Hongqi Town, Jinwan District, Zhuhai City, Guangdong Province, China

Copyright © 2026 singoo Technical supp

  • Whatsapp

  • Inquiry

Contact US

×