FURI-PRO Cooled High-Sensitivity Spectrometer

The FURI-PRO is the cooled version of the FURI long-focal-length spectrometer. The same 2048 x 64 area CCD sits behind the same F/4 crossed Czerny-Turner bench, but the detector is now cooled by a single-stage thermoelectric element, which cuts the dark current and with it the noise floor. The effect on the specification is direct: signal-to-noise ratio rises from 450:1 to 1000:1 at full signal and the dynamic range from 2100:1 to 4400:1 in a single acquisition. That is what makes a 0.11 nm resolution usable on a weak signal, because a long integration time no longer fills the spectrum with dark-current shot noise. The range is 200 to 1100 nm, stray light stays below 1 %, the A/D is 16 bit, the integration time runs from 2.4 ms to 10 s and the body weighs 1.25 kg, slightly more than the uncooled version because of the cooler and its heat path.

Email: marketing@longtec.com

Tel: 00864007808806

Whatsapp: 8618269775217

REQUEST A QUOTE
Main Functions
Applications
Spec Sheet
FAQ
Main Functions

· Single-stage TEC cooling of the 2048 x 64 area CCD cuts dark current, which is what a long integration time needs.

· Signal-to-noise ratio of 1000:1 at full signal, more than double the uncooled FURI-ST at the same resolution.

· Dynamic range of 4400:1 in a single acquisition, so trace bands survive beside strong emission lines.

· 0.11 nm optical resolution at the narrow-slit end, with stray light below 1 % and a 16-bit A/D.

· Integration time from 2.4 ms to 10 s, covering a transient and a multi-second weak-signal accumulation.

· 1.25 kg housing with SMA905 input, USB 2.0 Type-B and digital I/O, on Windows 7, 10 or 11.

Applications

The FURI-PRO is used for low-light Raman and fluorescence, where the signal is weak and the integration time long: trace detection, SERS substrates, biological fluorophores, phosphorescence with a millisecond-to-second decay, and emission from plasma or combustion where the interesting lines sit next to a bright continuum. It is also used for absorbance measurement at high optical density and for any laboratory method where the limiting factor is the detector noise rather than the optics.

Spec Sheet

FURI-PRO spec table

FAQ

How much does cooling actually help?

It removes dark-current shot noise, which grows with integration time. At 1 ms the difference against the uncooled version is small; at 1 s it is the difference between a usable spectrum and a noisy one. That is why the SNR and dynamic range figures are more than double.

Do I have to wait for the cooler to stabilise?

Yes. The detector needs a few minutes to reach its set temperature before a quantitative measurement, and the dark spectrum should be taken after that. Once stable, the baseline holds for a long session.

Is the resolution the same as the FURI-ST?

Yes, 0.11 to 3.42 nm depending on the slit. The optics are the same bench; what changes is the detector cooling and, with it, the noise floor.

What about the extra 180 g?

That is the cooler, its heat spreader and the extra housing. The instrument is still a benchtop module; it needs free air around the housing so the heat can leave, and it should not be boxed in without ventilation.

Which applications justify the cooled version?

Any measurement where the integration time is longer than a few tens of milliseconds, or where the signal is close to the detector noise: trace Raman, SERS, fluorescence, phosphorescence, and high-OD absorbance. For bright sources and short exposures the uncooled FURI-ST is enough.

Related Products

IM2000 Online Infrared Moisture AnalyzerIM2000 Online Infrared Moisture Analyzer
IM1500 Online Infrared Thickness GaugeIM1500 Online Infrared Thickness Gauge
HV200 Online High-Frequency Radar Moisture AnalyzerHV200 Online High-Frequency Radar Moisture Analyzer
RF2500 Online Variable-Frequency Radar Grain Moisture AnalyzerRF2500 Online Variable-Frequency Radar Grain Moisture Analyzer
ZA1000 Benchtop NIR Composition AnalyzerZA1000 Benchtop NIR Composition Analyzer
UD66 Online NIR Composition AnalyzerUD66 Online NIR Composition Analyzer
LONGTEC

Solutions & Support

We go the extra mile to thoroughly analyze each project and deliver tailored business solutions that meet your specific requirements.

  • TR200H Analog Weighing Signal Transmitter
  • TR700L Digital Weight Transmitter
  • UNI800S Digital Weight Transmitter
  • UNI900D3 Digital Weighing Instrument
  • IM2000 Online Infrared Moisture Analyzer
  • Company Profile
  • Why Choose Us 
  • Certificates
  • Company Partners
  • Privacy Policy
  • Tel: 400-7808-806
  • E-mail:marketing@longtec.com
  • Address:No. 3 Jinliang Road, Hongqi Town, Jinwan District, Zhuhai City, Guangdong Province, China

Copyright © 2026 singoo Technical supp

  • Whatsapp

  • Inquiry

Contact US

×